摘 要:探討了HVI恒溫恒濕實驗室在質量驗收中如何引用規(guī)范、測試標準器的選用、測試方法以及測試結果的數(shù)據(jù)處理等,以確定一個更適宜的測試方法實現(xiàn)對恒溫恒濕實驗室的驗收。HVI實驗室屬高精度恒溫恒濕實驗室,其建設的技術含量很高,難度較大,不同的測試方法可能會有不同的測試結果,適宜的驗收方法是建設質量評估的關鍵。
關鍵詞:HVI;恒溫恒濕;測試方法;驗收;探討
中圖分類號:TB22, X830.2 文獻標識碼:A
文章編號:1672-4984(2008)01-0047-03
Study on test method for acceptance checking of HVI constant
temperature and humidity laboratory
WU Chun-ai, SHENG Gao-shan, MENG Xian-luo
(Hebei Weather Technique Material Center,Shijiazhuang 050021,China)
Abstract: In order to determine the best suitable test method in the quality approval process of the HVI constant temperature constant humidity laboratory, the authors have discussed ways on how to quote the standards and how to select the test standard, the test method, as well as how to process the data of the test results and so on. The HVI laboratory is a high accuracy, constant temperature, and constant humidity laboratory. Due to its high technical content and technical difficulty in its construction, different test methods could possibly give very different test result, thus the finding of a suitable approval method is the key to build a better quality appraisal procedure.
Key words: HVI; Constant temperature constant humidity; Test method; Check; Investigation
Editor:liyan