  • 燈盞花素葡萄糖注射液包裝安瓿瓶中元素遷移性方法研究
    中國測(cè)試呂 昊1,2, 張玉蘭1, 孫羽婕1, 歐陽玉平3, 孫嗣旸1, 胡雅琴1
    摘  要:以濕法消解對(duì)低硼硅玻璃安瓿瓶包裝的燈盞花素葡萄糖注射液進(jìn)行消解,建立ICP-AES及ICP-MS測(cè)定其中Al、Ca、K、Na等14種元素的方法,并從檢出限、定量限、重復(fù)性等方面進(jìn)行驗(yàn)證。結(jié)果表明:該方法檢出限為0.009 ng/mL(Ni)~0.03 μg/mL(Al);定量限為0.03 ng/mL(Ni)~0.09 μg/mL(Al)。平均加標(biāo)回收率介于95.6%~101.4%之間。
    關(guān)鍵詞:燈盞花素;元素遷移;ICP-AES;ICP-MS
    文獻(xiàn)標(biāo)志碼:A       文章編號(hào):1674-5124(2015)12-0036-05
    Study on element migration in ampoules of scutellarin glucose injection
    LvHao1,2, ZHANG Yulan1, SUN Yujie1, OUYANG Yuping3, SUN Siyang1, HU Yaqin1
    (1. National Institute of Measurement and Testing Technology,Chengdu 610021,China;
    2. Analytical and Testing Center of Sichuan University,Chengdu 610061,China;
    3. Jilin Sichang Pharmaceutical Limited Company,Meihekou 135000,China)
    Abstract: A method with ICP-AES and ICP-MS has been established to determine the Al, Ca, K and Na and ten other elements in scutellarin glucose injection contained in low-borosilicate glass ampoules by means of wet digestion. The method has been verified in respect to detection limit, quantitative limit, repeatability, etc. The detection limit is 0.009 ng/mL(Ni)-0.03 μg/mL(Al), the quantitative limit is 0.03 ng/mL(Ni)-0.09 μg/mL(Al), and the average recovery is 95.6%-101.4%.
    Keywords: scutellarin; element migrate; ICP-AES; ICP-MS
     
     