摘 要:采用毛細(xì)管氣相色譜法(CGC)分別對二羥二丁基醚(DHDB)及手性雜質(zhì)的分離條件進(jìn)行考察,建立二羥二丁基醚(DHDB)含量的測定方法。PEG-20M(30 m×0.53 mm×1.0 μm)毛細(xì)管柱為色譜柱,F(xiàn)ID為檢測器,正辛醇作為內(nèi)標(biāo),DHDB手性雜質(zhì)程序升溫條件為初溫120 ℃,以0.5 ℃/min升溫至180 ℃,保持40 min;DHDB含量測定程序升溫條件為140 ℃保持1 min,以20 ℃/min升至200 ℃。DHDB及其手性異構(gòu)體得到完全分離;DHDB在66.70~800.1 μg/mL的范圍具有良好的線性關(guān)系(y=0.007 0x+0.055 4;r2=0.999 6);平均回收率為99.54%,重復(fù)性RSD為0.68%,中間精密度RSD為0.95%,樣品的平均含量為77.92%(RSD=0.25%)。該方法快速、簡便,適于DHDB手性雜質(zhì)分析和含量測定。
關(guān)鍵詞:毛細(xì)管GC;二羥二丁基醚;手性雜質(zhì);含量測定
文獻(xiàn)標(biāo)志碼:A 文章編號:1674-5124(2015)12-0041-04
CGC separation of DHDB and chiral impurities
ZHANG Yuxia, LI Dan, LIN Jie, KANG Tianyi, CHEN Furong, NING Xin, XU Xiaoping
(School of Pharmacy,Sichuan University,Chengdu 610041,China)
Abstract: Capillary Gas Chromatography(CGC) has been adopted to determine the content of dihydroxydibutylether(DHDB) based on the separation conditions of DHDB and its chiral impurities. Chromatographic column:PEG-20M capillary column (30 m×0.53 mm×1.0 μm); detector: flame ionization detector (FID); internal standard (IS):n-Octano. The separation conditions of DHDB and its chiral impurities are as follows:The column temperature was programmed from 120 ℃ to 180 ℃ at the rate of 0.5 ℃/min and then stayed there for 40 min. The assaying conditions of DHDB are as follows:The column temperature stayed at 140 ℃ for one minute and then programmed to 200 ℃ at the rate of 20 ℃/min. DHDB and its chiral impurities have been completely separated. The liner relationship of DHDB is good within the range of 66.70 μg/mL to 800.1 μg/mL(y=0.007 0x+0.055 4; r2=0.999 6). The average recovery, repeatability RSD, intermediate precision RSD and mean content are 99.54%, 0.68%, 0.95% and 77.92% (RSD=0.25%) respectively. The two chromatographic conditions established are suitable for separating DHDB from its chiral impurities and determining the content of DHDB. It is convenient, fast and practical.
Keywords: CGC; dihydroxydibutylether; chiral impurities; content detecting